The ballast (resistor ballast) is a device for limiting the flow of sunlight and generating instantaneous high pressure. Following is some difference between the electronic ballast and inductance ballast.

  1. Inductance Ballast is an iron core inductance coil, the inductance characteristic is when the current changes in the coil, the magnetic flux changes, resulting in the induction electromotive, its direction and current changes in the opposite direction, thus impeding the current changes. And usually used in fluorescent lamps.
  1. Electronic ballast, is one kind of ballast, refers to the use of electronic technology driven electric light source, so that to produce required electronic equipment. Comparatively, is an inductive ballast (or ballast) Today fluorescent lamps more and more designed with electronic ballast, light and compact, and even can be integrated with electronic ballast and lamp, at the same time, the electronic ballast can have both the functions of the Rev. So, the individual Rev may be omitted.
  1. Electronic ballast have much more features, such as improving the current frequency or current waveform (such as the use of a square wave) to improve or eliminate the flicker phenomenon of the fluorescent lamp. Some disadvantages of the traditional inductive rectifier are being replaced by the growing electronic ballast.

From the circuit:

  1. Inductance Ballast with large power frequency inductance and starter, inductance in the power of the flash with the power to produce high voltage to light the tube, and then start the work of the device to stop working, inductance play a limited role. And now the general use of electronic ballast directly used in the principle of switching power supply of high voltage light tube, then there are inductors limiting, but because the frequency is high, the inductance is very small.
  2. Inductance Ballast circuit is simple, and electronic is more complex.

From the effect:

  1. Electronic is easy to start, and adapt to a wide range of voltage. While the inductance hard to start on the condition of the low voltage.
  2. Electronic frequency is high, the lamp flashing can not be sensed, and the inductance is power frequency, can feel the flashing.
  3. in the inductance of silicon steel sheet loose will have a sound, and the electronic time does not have this problem.
  4. Inductance Ballast is more durable, not easy to break, and some electronic products, especially the low quality without warranty are easily to work wrong.

Electronic ballast has great advantage compared with traditional Inductive ballast, is gradually replacing the traditional inductive ballast lighting market. The main advantages are:

(1) Energy saving. The fluorescent lamp operating frequency is 50 Hz by Traditional inductive ballast. And the fluorescent lamps operating frequency is 30 ~ 50 Hz by electronic ballast. It is proved that fluorescent lamps operate at this frequency; brightness increased 14% operating at 50 Hz. That is when the fluorescent lamp reached the same light output, electronic ballast can transfer low output power to fluorescent lamp.

(2)The traditional inductive ballast with the power consumption is greater than the electronic ballast.

(3) Electronic ballast can greatly reduce the network load and power loss.

Requirements for starting conditions:

  1. Temperature: inductive ballast start with low excitation energy, therefore, it is necessary to normally start at 10℃ , while the electronic ballast can even start at -25℃.
  2. Voltage inductance ballast can not start when the power supply voltage is less than 180 V, the electronic ballast can normally start when the grid voltage is 100 V.

Influence on the tube life:

(1) Influence of start process on the tube life: inductive ballast need to start several times before the fluorescent lamp can be lighted and each time will shorten the 2h life. Electronic ballast, whether in low temperature or low voltage conditions, can start after filament preheating.

(2) Influence of the power network voltage fluctuation on the life of the lamp tube: when the lamp is working with the fluorescent lamp, the lamp current changes with the voltage of the electric network. When the power grid voltage is low, the lamp current decreases. Lamp current reduce will result in insufficient heating filament, filament electronic powder sputtering, resulting in both sides of the lamp blackening and shorten the life of the lamp tube. When the power supply voltage is high, the lamp current will increase which will result in the premature failure of the filament and the fluorescent powder and shorten the life of the lamp. Electronic ballast can do in the 135 ~ 250 V power grid voltage range, on changes on lamp current so that the fluorescent lamp is always working in the best condition, thence greatly improving the life of the lamp.

Lisun launched WT5000 electronic ballast synthesis test instrument to meet the IEC60929, IEC60969, IEC61000-3-2, GB/T15144-2005, GB/T17263-1998 etc. the latest international and domestic standards and applied in the testing of electronic ballast. Lisun Electronics (Shanghai) Co., Ltd is engaged in lighting test equipment, environmental test equipment, EMI / EMC testing system and safety test instrument in the domestic market development and after-sales maintenance. Lisun products are fully according to the quality management and control of ISO9001:2008 requirements for R & D and production; Lisun is also the global lighting CIE Association member, all products meet CIE requirements; in addition, Lisun products are certified by CE and get the qualification of the EU.

Related posts:

  1. The Applications of Electronic Ballast
  2. Inductive energy storage current solution
  3. The EMI Suppression Technology of Electronic Ballast
  4. EMC: Inductive Energy Storage Current Solution
  5. The EMI Filter Current of Electronic Ballast
  6. Lisun Group Products List Part8: Electronic Ballast Tester
  7. The special requirements for HID lamp electronic ballasts
  8. Type A LED tube test
  9. Equivalent Test Between Normal & High Frequency Fluorescent Lamp and LED Tube
  10. Online Video: WT5000 Electronic Ballast Ballast Tester
  11. What is the difference between IEC/ EN 60825-1 and IEC/ EN 62471?
  12. A brief of the Harm and Production Principle of Stroboscopic
  13. Flashing Effect of the Light Source and the Measuring Method|Part2: Causes of Light Source Flashing
  14. Low frequency harmonic current suppression filter solution
  15. The optical proper of LED has obvious difference in different temperature.
  16. The relationship of LED lighting and power factor
  17. Color Difference SDCM
  18. The difference between main optical names of LED
  19. ATE-1 Electronic Ballast Automatic Test Equipment
  20. The Conducted Interference Sources of Electronic Ballasts
  21. Electronic Load of the LED Power Supply Test
  22. The Main Electromagnetic Disturbance Source of Electronic and Electrical Products
  23. Electronic, electrical products’ intermittent conduction emission of exceeding standard problems and the countermeasures & Electronic electrical products radiation harassment of exceeding-standards and the countermeasures
  24. The Difference between LED Light Sources
  25. Flashing Effect of the Light Source and the Measuring Method|Part3: Flashing Harm to Human Eyes
  26. Electromagnetic Compatibility (EMC) Design for Vehicle Electronic Equipment 2
  27. Difference Between the Electrostatic Generator and Electrostatic Discharge Generator
  28. Power Saving and Environmental Protection
  29. Main Electromagnetic Interference Source Within the Electronic and Electrical products
  30. What is the LED MCOB Package? The Difference between MCOB and LED COB Package
  31. What is Electronic Load and How to Use It Correctly?
  32. Other countermeasures against the harmonic problem – EMC Testing
  33. The difference between Electrostatic Discharge Simulator and Electrostatic Generator
  34. The testing rules of lighting product
  35. LED Power Drive
  36. The present situation of the LED luminaires and reliability life test
  37. Radiation Harassment Overweight Problems and Countermeasures of Electronic and Electrical Products
  38. How to effective to measuring LED lamp Start, Run up time and Flicker
  39. How to Design A LED Power Driver
  40. LED solid-state lighting products Introduction
  41. Continuous Conducted Emission Overweight and Intermittent Conduction Emission Overweight Problems and Countermeasures of Electronic and Electrical Products
  42. Pros and Cons of LED Lamp
  43. Electromagnetic Compatibility (EMC) Design for Vehicle Electronic Equipment 1
  44. The research on the reliability of high power white LED
  45. High-Frequency Current-Voltage Characters Measurement
  46. Testing requirements and advantages of LED lights applied in the automotive market
  47. The Method of Measuring LEDs and LED Luminaires Flicker
  48. The Methods and Principles of Applying Interference for LED Lighting Burst Test
  49. Testing Rules for Lighting Products Part2: Low Temperature Test and High Pressure Experiment
  50. The Introduction of High Power White LED
  51. EMI Test
  52. Flashing Effect of the Light Source and the Measuring Method|Part1: Basic Concept of Flashing
  53. How to effective to measuring LED lamp Start, Run up time and Flicker
  54. The Dimming Method
  55. LED Lamps Aging and Life Test
  56. Color Rendition Index CRI
  57. Understand the atomic structure and electronic properties when spectral analysis
  58. Flashing Effect of the Light Source and the Measuring Method|Part5: Flashing Results of the Typical Light Source
  59. Video of WT3000 Electric Ballast Tester
  60. The Differences between LED and OLED
  61. Lisun Group Products List Part9: Electronic Components Tester
  62. How to design the secondary constant current of LED power
  63. How to choose LED light source
  64. Input/Outpur protection against abnormal load
  65. Standard LM-79 and LM-80 comparison
  66. Interference Way for Group Pules Generator Test
  67. Introduction of Measurement Standard for Harmonic Current
  68. LED Lamp for Film and Television
Posted in Industry Knowledge | Tagged Electronic Ballast
← Previous Next →
Lisun-Group-Logo

Lisun Website

English
中文
Español
Pусский

Contact Us:
Email: Sales@Lisungroup.com
Skype: lisungroup2003
Phone: +86 18917996096

Test Service For Free

Free Service for LED Lamps Testing (IES file report, Light distribution curve, Total lumen, CCT, CRI, etc)

Important Industry Knowledge

CIE Published Latest CIE S025 LED Test Standard
IESNA-LM-80 for LED Lumen Maintenance Test
According to IESNA-LM-79, How to Choose the Integrating Sphere and Goniophotometer?

Archives

  • January 2019 (4)
  • December 2018 (7)
  • November 2018 (4)
  • October 2018 (7)
  • September 2018 (2)
  • August 2018 (6)
  • July 2018 (12)
  • June 2018 (8)
  • May 2018 (10)
  • April 2018 (3)
  • March 2018 (9)
  • February 2018 (3)
  • January 2018 (8)
  • December 2017 (10)
  • November 2017 (17)
  • October 2017 (2)
  • September 2017 (12)
  • August 2017 (7)
  • July 2017 (3)
  • June 2017 (10)
  • March 2017 (1)
  • January 2017 (3)
  • December 2016 (5)
  • November 2016 (4)
  • October 2016 (5)
  • September 2016 (5)
  • August 2016 (4)
  • July 2016 (4)
  • June 2016 (5)
  • May 2016 (5)
  • April 2016 (7)
  • March 2016 (6)
  • February 2016 (6)
  • January 2016 (6)
  • December 2015 (9)
  • November 2015 (6)
  • October 2015 (2)
  • September 2015 (4)
  • August 2015 (6)
  • July 2015 (5)
  • June 2015 (8)
  • May 2015 (8)
  • April 2015 (8)
  • January 2015 (1)
  • December 2014 (1)
  • November 2014 (4)
  • October 2014 (5)
  • September 2014 (9)
  • August 2014 (4)
  • July 2014 (4)
  • June 2014 (3)
  • May 2014 (8)
  • April 2014 (7)
  • March 2014 (12)
  • February 2014 (7)
  • January 2014 (12)
  • December 2013 (10)
  • November 2013 (11)
  • October 2013 (12)
  • September 2013 (11)
  • August 2013 (12)
  • June 2013 (2)
  • May 2013 (4)
  • April 2013 (4)
  • March 2013 (1)
  • February 2013 (1)
  • January 2013 (9)
  • December 2012 (12)
  • November 2012 (8)
  • October 2012 (3)
  • September 2012 (6)
  • August 2012 (5)
  • July 2012 (14)
  • June 2012 (6)
  • May 2012 (16)
  • April 2012 (18)
  • March 2012 (18)
  • February 2012 (19)
  • January 2012 (15)
  • December 2011 (24)
  • November 2011 (16)
  • October 2011 (28)
  • September 2011 (8)

Search

Our Products

Goniophotometer
Spectroradiometer
Integrating Sphere
Colorimeter
Photometer
Brightness Meter
Luminance Meter
Pocket Colorimeter
Color Temperature Meter
LED Aging Tester
LED Driver Testing
High Frequency Power Supply
Resistance Ballast
Reference Ballast
High Frequency Current Source
Digital Torsion Meter
Go no go Gauge
EMC Test Equipment
EMI Test Equipment
EMI Receiver
ESD Generator
EFT Immunity Test
Surge Generator
Voltage Dip Generator
Ring Wave Generator
Electronic Ballast Tester
Electrical Safety Tester
Glow-wire Tester
Needle Flame Test
Leakage Current Test
Insulation Resistance Tester
Withstand Voltage Test
Oscilloscope
Environmental Test Chamber
Temperature Humidity Chamber
Waterproof Tester
Dust Test Chamber
IK Test
Salt Spray Test
RoHS Testing
AC and DC Power Supply
Adjustable DC Power Supply
Constant Current Power Supply
Digital Power Meter
Harmonic Analyzer
AC and DC Power Meter

Sitemap

Copyright © 2019 Lisun Group.

Powered by WordPress and Retro-fitted.